The new aluminum alloy gas turbine flowmeter is coming
2020-11-13
Aluminum alloy gas turbine flowmeter
View detailsClassification of measurement principles_this is a test
2020-08-26
Classification of measurement principles 1. Mechanics principles: instruments that belong to this type of principle include differential pressure type and rotor type using Bernoulli theorem; impulse type and movable tube type using momentum theorem;
View detailsReasons for inaccurate measurement of vortex flowmeter (part 2)
2020-08-20
?1. The transmitter of the vortex flowmeter stops the abnormal whistling sound: (1) The flow rate is too high, causing the generator or detection element to vibrate; (2) Cavitation occurs in the pipeline; (3) The generating body or detecting element is loose. Solution: In order to avoid damage to the generating body or detection components, the valve should be adjusted first to reduce the flow rate and the flow rate, and then further investigate the cause.
View detailsReasons for inaccurate measurement of vortex flowmeter (part 1)
2020-08-19
1. The vortex flowmeter is powered on, the valve is not open, and there is signal output. Solution: ①The shielding or grounding of the output signal of the sensor (or detection element) is poor, which induces external electromagnetic interference; ②The meter is too close to the strong current equipment or high-frequency equipment, and the space electromagnetic radiation interference will affect the meter;
View details