Thermal gas mass flow meter
適用介質Gas
不適用介質Liquid
Introduction
Thermal gas mass flow meter contains two platinum resistance temperature sensors. The thermal principle operates by monitoring the cooling effect of a gas stream as it passes over a heated sensor. Gas flowing through the sensing section passes over two sensors one of which is used conventionally as a temperature sensor, whilst the other is used as a heater. The temperature sensor monitors the actual process values whilst the heater is maintained at a constant differential temperature above this by varying the power consumed by the sensor. The greater the gas velocity, the greater the cooling effect and power required to maintain the differential temperature. The measured heater power is therefore a measure of the gas mass flow rate.
Features
Measuring the mass flow or volume flow of gas
Do not need to do temperature and pressure compensation in principle?with accurate measurement and easy operation.
Wide range: 0.5Nm/s~100Nm/s for gas. The meter also can be used for gas leak detection
Good vibration resistance and long service life. No moving parts and pressure sensor in transducer, no vibration influence on the measurement accuracy.
Easy installation and maintenance. If the conditions on site are permissible, the meter can achieve a hot-tapped installation and maintenance. (Special order of custom-made)
Digital design, high accuracy and stability
Configuring with RS485 or HART interface to realize factory automation and integration
Technical parameters
Description |
Specifications |
Measuring Medium |
Various gases (Except the acetylene) |
Pipe Size |
DN15~DN1600mm |
Velocity |
0.1~100 Nm/s |
Accuracy |
±1~2.5% |
Working Temperature |
Sensor: -40℃~+220℃ Transmitter: -20℃~+45℃ |
Insertion Sensor: medium pressure≤ 1.6MPa Flanged?Sensor: medium pressure≤ 1.6MPa Special pressure please contact us |
|
Power Supply |
Compact type: 24VDC or 220VAC, Power consumption ≤18W Remote type: 220VAC, Power consumption ≤19W |
Response Time |
1s |
Output |
4-20mA (optoelectronic isolation, maximum load 500Ω), Pulse, RS485 (optoelectronic isolation)and HART |
Alarm Output |
1-2 line Relay, Normally Open state, 10A/220V/AC or 5A/30V/DC |
Sensor Type |
Standard Insertion, Hot-tapped Insertion?and Flanged |
Construction |
Compact and Remote |
Pipe Material |
Carbon steel, stainless steel, plastic, etc |
Display |
4 lines LCD Mass flow, Volume flow in standard condition, Flow totalizer, Date and Time, Working time, and Velocity, etc. |
Protection Class |
IP65 |
Sensor Housing Material |
Stainless steel 316 |
在線留言