Insertion type vortex flow meter
適用介質(zhì)gas, liquid, steam
不適用介質(zhì)
Introduction
Insertion vortex flow meter is used in numerous branches of industry to
measure the volume flow of liquids, gases and steam. Applications in the
chemicals and petrochemicals industries, for example, in power
generation and heat-supply systems involve widely differing fluids:
saturated steam, superheated steam, compressed air, nitrogen, liquefied
gases, flue gases, carbon dioxide, fully demineralized water, solvents,
heat-transfer oils, boiler feedwater, condensate, etc.
Features
?
1. Simple structure,? no moving parts, high reliability
2. Suitable size DN200--600.
3. High accuracy 1.5%, 2.5%
4. Resist high temperature up to 350℃,normal temperature up to 250℃
5. Integral forging, anti-rust, long service life
6,Less pressure loss, lower operating costs, more energy-saving significance.
Specifications
Measuring diameter |
DN200~600 |
Relative humidity |
5℃~90℃ |
Atmospheric pressure |
86~106kPa |
Medium temperature |
Standard: -40℃~+250℃ High temperature: -40℃~+350℃ |
Nominal pressure |
1.6MPa;2.5MPa;4.0MPa;6.3MPa |
Media type |
Liquid, gas, steam |
Accuracy class |
Liquid 1.5% gas, steam 2.5% |
Power supply |
12~24V DC, battery power |
Output signal |
4~20mA |